1.
J Biomech Eng ; 143(10)2021 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-34008848

RESUMO

Rotator cuff (RC) tears cause pain and functional disability of the shoulder. Despite advances in suture anchors, there are still reports about the incidence of surgical-related injuries to RC mainly associated with sutures. The purpose of this study was to design and evaluate the mechanical behavior of sutureless implants to repair RC tears. We hypothesized that the implants present mechanical characteristics suitable for the surgical treatment of RC tears as suture anchors. Three different implants (T1, T2, T3) were designed and fabricated with titanium: T1 has two rods and rectangular head; T2 has two rods with a small opening and enlarged rectangular head; and T3 has three rods and a circular head. The implants were fixed in rigid polyurethane foam blocks by a series of blows, and the applied mechanical loads along with the number of blows were quantified. Pullout tests using tapes fixed between the implant head and testing machine grip were conducted until implant failure. The maximum pullout strength and displacement of the implant relative to the rigid foam block were computed. Statistical significance was set at p < 0.05. Owing to its geometric configuration, implant T2 presented the best characteristics related to stability, strength, and ease of insertion. Implant T2 confirms our hypothesis that its mechanical behavior is compatible with that of suture anchors, which could lead to the reduction of RC repair failures and simplify the arthroscopic procedure.


Assuntos
Lesões do Manguito Rotador
2.
Rev Lat Am Enfermagem ; 26: e3083, 2018 Nov 29.
Artigo em Inglês, Português, Espanhol | MEDLINE | ID: mdl-30517574

RESUMO

OBJECTIVE: to evaluate the interface pressure (IP) of support surfaces (SSs) on bony prominences. METHOD: a quasi-experimental study with repeated measures on each SS. Twenty healthy adult volunteers participated in the study. The participants were placed in the supine position on a standard operating table for evaluation of IP on the bony prominences of the occipital, subscapular, sacral, and calcaneal regions using sensors. Seven evaluations were performed for each bony prominence: one on a standard operating table, and the others on tables containing SSs made of viscoelastic polymer, soft foam, or sealed foam. Descriptive statistics and analysis of variance were used to analyze the data. RESULTS: the mean IP was higher on the viscoelastic polymer-based SS compared to the other SSs (p<0.001). The mean IP was relatively lower on the density-33 sealed foam and density-18 soft foam. In addition, this variable was comparatively higher in the sacral region (42.90 mmHg) and the calcaneal region (15.35 mmHg). CONCLUSION: IP was relatively lower on foam-based SSs, especially on density-18 soft foam and density-33 sealed foam. Nonetheless, IP was not reduced on the viscoelastic polymer SS compared to the control SS.


Assuntos
Salas Cirúrgicas , Mesas Cirúrgicas , Posicionamento do Paciente/instrumentação , Assistência Perioperatória , Lesão por Pressão/prevenção & controle , Adulto , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
3.
Biosci. j. (Online) ; 34(6): 1824-1834, nov.-dec. 2018. ilus, graf
Artigo em Inglês | LILACS | ID: biblio-968982

RESUMO

One of greatest challenges of dentists is the rehabilitation of free-end Kennedy class I and class II patients due to the improper occurrence of stress around the supporting structures of conventional removable dentures during mastication. This work aimed to compare the stress distribution in different prosthetic solutions. For this analysis, four photoelastic models (PM) were produced simulating a Kennedy class I arch with the remaining teeth 34 through 44. In all models, teeth 33, 34, 43, and 44 received metal crowns. In addition to the crowns, the A model (PMA) received a conventional removable partial denture (RPD), the B model (PMB) received a RPD associated with a semi-rigid attachment, the C model (PMC) received a RPD associated with a rigid attachment, and the D model (PMD) received a RPD associated with implant and rigid attachment. Evenly distributed loads were applied on the last artificial tooth of the prostheses. Based on the results of the distributed load, the conventional prosthesis presented the best results for all regions (averages ranging from 25.70 to 17.80), followed by the prosthesis associated with the implant, the prosthesis associated with the rigid attachment, and lastly, the prosthesis associated with the semi-rigid attachment. The same result can be observed in the localized load, where the conventional prosthesis presented superior results in all regions (averages ranging from 47.35 to 8.30), followed by the prosthesis associated with the implant, the prosthesis associated with the rigid attachment and, with the prosthesis associated with the semi-rigid attachment. Based on the data obtained, it may be concluded that the conventional RPD presented a balanced stress distribution in the three regions analyzed, and when associated with the semi-rigid attachment, it presented a more favorable behavior than that associated with the rigid attachment.


Um dos maiores desafios para os cirurgiões-dentistas consiste na reabilitação de pacientes com extremidade livre classe I e classe II de Kennedy, devido à ocorrência inadequada de tensão em torno das estruturas de suporte das próteses removíveis convencionais durante o processo da mastigação. O objetivo deste trabalho foi analisar comparativamente a distribuição de tensão em diferentes soluções protéticas. Para essa análise, foram confeccionados quatro Modelos Fotoelásticos (MF) simulando um arco classe I de Kennedy, e tendo como dentes remanescentes do dente 34 ao 44. Em todos os modelos, os dentes 33, 34, 43 e 44 receberam coroas metálicas. Além das coroas, o modelo A (MFA) recebeu uma Prótese Parcial Removível (PPR) convencional, o modelo B (MFB) recebeu uma PPR associada a encaixe semirrígido, o modelo C (MFC) recebeu uma PPR associada a encaixe rígido e o modelo D (MFD) recebeu uma PPR associada a implante e encaixe rígido. Foram aplicadas cargas uniformemente distribuídas e localizadas no último dente artificial das próteses. Baseado nos resultados da carga distribuída, a prótese convencional apresentou os melhores resultados para todas as regiões (médias variando entre 25,70 e 17,80), seguida da prótese associada ao implante, a prótese associada ao encaixe rígido e, finalmente, com a prótese associada ao encaixe semirrígido. O mesmo resultado pode ser observado na carga localizada, onde a prótese convencional apresentou resultados superiores em todas as regiões (médias variando entre 47,35 e 8,30), seguida da prótese associada ao implante, a prótese associada ao encaixe rígido e, finalmente, com a prótese associada ao encaixe semirrígido. Baseado nos dados obtidos pôde-se concluir que a PPR convencional apresentou uma distribuição equilibrada de tensões nas três regiões analisadas e, quando associado à fixação semi-rígida, apresentou um comportamento mais favorável do que aquele associado à fixação rígida.


Assuntos
Prótese Parcial Removível , Prostodontia , Dente Artificial , Implantes Dentários , Dentaduras , Prótese Dentária
4.
Rev. latinoam. enferm. (Online) ; 26: e3083, 2018. tab, graf
Artigo em Inglês | LILACS, BDENF - Enfermagem | ID: biblio-978621

RESUMO

Abstract Objective: to evaluate the interface pressure (IP) of support surfaces (SSs) on bony prominences. Method: a quasi-experimental study with repeated measures on each SS. Twenty healthy adult volunteers participated in the study. The participants were placed in the supine position on a standard operating table for evaluation of IP on the bony prominences of the occipital, subscapular, sacral, and calcaneal regions using sensors. Seven evaluations were performed for each bony prominence: one on a standard operating table, and the others on tables containing SSs made of viscoelastic polymer, soft foam, or sealed foam. Descriptive statistics and analysis of variance were used to analyze the data. Results: the mean IP was higher on the viscoelastic polymer-based SS compared to the other SSs (p<0.001). The mean IP was relatively lower on the density-33 sealed foam and density-18 soft foam. In addition, this variable was comparatively higher in the sacral region (42.90 mmHg) and the calcaneal region (15.35 mmHg). Conclusion: IP was relatively lower on foam-based SSs, especially on density-18 soft foam and density-33 sealed foam. Nonetheless, IP was not reduced on the viscoelastic polymer SS compared to the control SS.


RESUMO Objetivo: valiar a pressão de interface (PI) das superfícies de apoio (SAs) em proeminências ósseas. Método: um estudo quase experimental com medidas repetidas em diferentes SAs. Vinte voluntários adultos saudáveis participaram do estudo. Os participantes foram colocados em decúbito dorsal em uma mesa cirúrgica para avaliação da PI nas proeminências ósseas das regiões occipital, subescapular, sacral e calcânea utilizando sensores. Sete avaliações foram realizadas para cada proeminência óssea: uma avaliação em uma mesa de operação padrão e as outras avaliações em mesas contendo SAs à base de polímero viscoelástico, espuma macia, ou espuma selada. Estatística descritiva e análise de variância foram utilizadas para analisar os dados. Resultados: a PI média foi maior na SA feita de polímero viscoelástico em comparação com as outras SAs (p<0,001). A PI média foi relativamente menor na espuma selada de densidade 33 e na espuma macia de densidade 18. Além disso, essa variável foi comparativamente maior na região sacral (42,90 mmHg) e na região calcânea (15,35 mmHg). Conclusão: a PI foi menor em SAs à base de espuma, especialmente espuma macia de densidade 18 e espuma selada de densidade 33. No entanto, a PI não foi reduzida na SA à base de polímero viscoelástico comparado com a SA controle.


RESUMEN Objetivo: evaluar la presión de interfaz (PI) de las superficies de apoyo (SAs) en prominencias óseas. Método: un estudio casi experimental con medidas repetidas en diferentes SAs. Veinte voluntarios adultos saludables participaron del estudio. Los participantes fueron colocados en decúbito dorsal en una mesa quirúrgica para evaluación de la PI en las prominencias óseas de las regiones occipital, subescapular, sacra y calcánea utilizando sensores. Siete evaluaciones fueron realizadas para cada prominencia ósea: una evaluación en una mesa de operación estándar y otras evaluaciones en mesas que contenían SAs a base de polímero viscoelástico, espuma blanda, o espuma sellada. Fueron utilizadas la estadística descriptiva y el análisis de la varianza para analizar los datos. Resultados: la PI media fue mayor en la SA hecha de polímero viscoelástico en comparación con las otras SAs (p<0,001). La PI media fue relativamente menor en la espuma sellada de densidad 33 y en la espuma blanda de densidad 18. Además, esa variable fue comparativamente mayor en la región sacra (42,90 mmHg) y en la región calcánea (15,35 mmHg). Conclusión: la PI fue menor en SAs a base de espuma, especialmente espuma blanda de densidad 18 y espuma sellada de densidad 33. Sin embargo, la PI no fue reducida en la SA a base de polímero viscoelástico comparado con la SA control.


Assuntos
Humanos , Masculino , Feminino , Assistência Perioperatória/normas , Lesão por Pressão/prevenção & controle , Posicionamento do Paciente/instrumentação , Mesas Cirúrgicas/normas
5.
Acta ortop. bras ; 22(1): 17-20, 2014. graf
Artigo em Inglês | LILACS | ID: lil-703992

RESUMO

Objective: To compare, using photoelasticity, internal stress produced by USS II type screw with 5.2 and 6.2 mm external diameters, when submitted to three different pullout strengths. Methods: Two photoelastic models were especially made. The simulation was performed using loads of 1.8, 2.4 e 3.3 kgf.The fringe orders were evaluated around the screws. In all the models analyzed the shear stress were calculated. Results: Independently of the applied load, the smaller screw showed higher values of shear stress. Conclusion: According to the analysis performed, we observed that the place of highest stress was in the first thread of the lead, close to the head of the screws. Experimental study. .

6.
Braz. dent. j ; 24(2): 147-151, Mar-Apr/2013. tab, graf
Artigo em Inglês | LILACS | ID: lil-675660

RESUMO

Lack of passivity has been associated with biomechanical problems in implant-supported prosthesis. The aim of this study was to evaluate the passivity of three techniques to fabricate an implant framework from a Co-Cr alloy by photoelasticity. The model was obtained from a steel die simulating an edentulous mandible with 4 external hexagon analog implants with a standard platform. On this model, five frameworks were fabricated for each group: a monoblock framework (control), laser and TIG welding frameworks. The photoelastic model was made from a flexible epoxy resin. On the photoelastic analysis, the frameworks were bolted onto the model for the verification of maximum shear stress at 34 selected points around the implants and 5 points in the middle of the model. The stresses were compared all over the photoelastic model, between the right, left, and center regions and between the cervical and apical regions. The values were subjected to two-way ANOVA, and Tukey's test (α=0.05). There was no significant difference among the groups and studied areas (p>0.05). It was concluded that the stresses generated around the implants were similar for all techniques.


Resumo A falta de passividade tem sido associada a problemas biomecânicos em próteses implantossuportadas. A proposta deste estudo foi avaliar, por meio da fotoelasticidade, a influência de três diferentes de fabricação de infraestrutura em liga de Co-Cr na passividade destas. O modelo foi obtido a partir de uma matriz de aço simulando uma mandíbula edêntula com 4 análogos de implantes de hexágono externo com plataforma padrão. Neste modelo, foram confeccionados cinco amostras para cada grupo: infraestruturas em monobloco, infraestruturas soldadas a laser e soldadas a TIG. O modelo fotoelástico foi feito com uma resina epóxi flexível (GIII, Polipox Industria e Comercio Ltda.). Na análise fotoelástica, as infraestruturas foram aparafusadas no modelo para a verificação da tensão de cisalhante máxima em 34 pontos selecionados ao redor dos implantes e 5 pontos na região média do modelo. Foram comparadas as tensões em todo o modelo fotoelástico, entre as regiões direita, esquerda e centro e também entre as regiões cervical e apical. Os valores foram submetidos à análise de variância a dois critérios, seguido pelo teste de Tukey (α=0,05). Os resultados não mostraram diferença significativa entre as tensões presentes nos grupos e nas áreas estudadas. Conclui-seque as tensões geradas ao redor dos implantes foram semelhantes entre as diferentes técnicas de confecção e entre todas as regiões analisadas. .


Assuntos
Humanos , Ligas de Cromo/química , Prótese Dentária Fixada por Implante , Soldagem em Odontologia/métodos , Lasers , Gases em Plasma , Técnica de Fundição Odontológica , Projeto do Implante Dentário-Pivô , Implantes Dentários , Modelos Dentários , Soldagem em Odontologia/instrumentação , Resinas Epóxi/química , Arcada Edêntula/reabilitação , Teste de Materiais , Mandíbula/patologia , Estresse Mecânico , Propriedades de Superfície , Soldagem/instrumentação , Soldagem/métodos
7.
Braz. dent. j ; 23(6): 686-691, 2012. ilus, tab
Artigo em Inglês | LILACS | ID: lil-662427

RESUMO

The aim of this study was to assess the effect of different plasma arc welding parameters on the flexural strength of titanium alloy beams (Ti-6Al-4V). Forty Ti-6Al-4V and 10 NiCr alloy beam specimens (40 mm long and 3.18 mm diameter) were prepared and divided into 5 groups (n=10). The titanium alloy beams for the control group were not sectioned or subjected to welding. Groups PL10, PL12, and PL14 contained titanium beams sectioned and welded at current 3 A for 10, 12 or 14 ms, respectively. Group NCB consisted of NiCr alloy beams welded using conventional torch brazing. After, the beams were subjected to a three-point bending test and the values obtained were analyzed to assess the flexural strength (MPa). Statistical analysis was carried out by one-way ANOVA and Tukey's HSD test at 0.05 confidence level. Significant difference was verified among the evaluated groups (p<0.001), with higher flexural strength for the control group (p<0.05). No significant differences was observed among the plasma welded groups (p>0.05). The NCB group showed the lowest flexural strength, although it was statistically similar to the PL 14 group (p>0.05). The weld depth penetration was not significantly different among the plasma welded groups (p=0.05). Three representative specimens were randomly selected to be evaluated under scanning electron microcopy. The composition of the welded regions was analyzed by energy dispersive X-ray spectroscopy. This study provides an initial set of parameters supporting the use of plasma welding during fabrication of titanium alloy dental frameworks.


O objetivo deste estudo foi avaliar o efeito de diferentes parâmetros de solda a plasma verificando a resistência flexural de barras de liga de titânio (Ti-6Al-4V). Quarenta espécimes de Ti-6AL-4V e dez espécimes de liga de NiCr foram preparados (40 mm de altura e 3,18 mm de diâmetro) e divididos em 5 grupos (n=10). As barras de liga titânio do grupo controle não foram seccionadas e nem submetidas a processo de soldagem. Os grupos PL10, PL12 e PL14, continham barras de titânio seccionadas e soldadas com uma corrente de 3 A por períodos de 10,12 e 14 ms, respectivamente. O grupo NCB consistiu de barras de liga de NiCr soldadas pelo método de brasagem convencional. Em seguida as barras foram submetidas ao teste de flexão de três pontos e os valores obtidos foram transformados em resistência flexural (MPa). Análise estatística foi realizada usando ANOVA de fator único e o teste Tukey com o nível de significância de 0,05. Diferença estatística foi verificada entre os grupos avaliados (p<0,001), com os maiores valores pra o grupo controle. Não foram encontradas diferenças entre os grupos de solda plasma (p>0,05). O grupo NCB apresentou os menores valores de resistência flexural embora tenha sido estatisticamente semelhante ao grupo PL14. Não houve diferença significante na profundidade de penetração entre os grupos de solda plasma (p=0,05). Três espécimes representativos foram aleatoriamente selecionados para serem avaliados por meio de microscopia eletrônica de varredura. A composição das regiões soldadas foi verificada por meio de espectroscopia por energia dispersiva. Este estudo fornece informações iniciais de parâmetros para permitir a utilização de soldagem plasma durante a fabricação de estruturas em liga de titânio.


Assuntos
Humanos , Ligas Dentárias/química , Soldagem em Odontologia/métodos , Gases em Plasma/química , Titânio/química , Argônio/química , Ligas de Cromo/química , Soldagem em Odontologia/instrumentação , Teste de Materiais , Microscopia Eletrônica de Varredura , Maleabilidade , Espectrometria por Raios X , Estresse Mecânico , Propriedades de Superfície , Soldagem/instrumentação , Soldagem/métodos
8.
Acta ortop. bras ; 17(3): 149-151, 2009. ilus
Artigo em Inglês, Português | LILACS | ID: lil-520010

RESUMO

INTRODUÇÃO: O sistema de fixação vertebral utilizando o parafuso pedicular é um dos métodos mais eficientes no tratamento de patologias da coluna vertebral. Quando o parafuso estiver submetido á força de arrancamento, este gera tensões ao seu redor, principalmente próximas do canal medular, situação esta que pode ser analisada pela técnica da fotoelasticidade. OBJETIVO: Foram analisadas as tensões internas geradas próximas ao canal medular de modelos fotoelásticos de vértebras utilizando diferentes medidas de parafusos do sistema de fixação vertebral submetidos à força de arrancamento. MÉTODO: Foi utilizado um modelo de vértebra lombar em material fotoelástico utilizando três medidas de parafusos pediculares (5, 6 e 7mm) do tipo USS1. As tensões internas ao redor do parafuso foram avaliadas em 12 pontos pré-determinados utilizando um polariscópio de transmissão plana. RESULTADOS: As regiões de maiores concentrações de tensões foram observadas entre o canal medular e as curvas do processo transverso. Nas comparações das médias das tensões cisalhantes máximas entre os parafusos 5 e 7, e 6 e 7 foram observadas diferenças estatísticas significativas e entre 5 e 6 não. CONCLUSÃO: Foi observada que as tensões internas são mais elevadas em áreas irregulares próxima ao canal medular, mostrando ser uma região crítica.


INTRODUCTION: The vertebrae fixation system using pedicular screws is one of the most efficient methods to treat vertebral spine pathologies. When the screw is submitted to pullout strength, it causes internal tension near the medullar canal and this situation can be analyzed by using the photoelasticity technique. OBJECTIVE: Were analyzed those internal tensions near the medullar canal of photoelastic vertebra models using different sizes of screws of the vertebral fixation system submitted to pullout strength. METHODS: A lumbar vertebral model made of photoelastic material with three different USS1-type pedicular screw sizes (5, 6, and 7mm) was used. The internal tensions around the screw were tested in 12 predetermined points by a plain transmission polaroscope. RESULTS: The areas of greater tension concentration were between the medullar canal and the curves of the transverse process. Comparing the maximum average pulling tension, statistical differences were observed between screws 5 and 7, and 6 and 7. On the other hand, for screws 5 and 6, there were no significant differences. CONCLUSION: The study evidenced that the internal tensions are greater in irregular areas, next to the medullar canal, showing that this is a critical region.


Assuntos
Humanos , Parafusos Ósseos , Fixadores Internos , Vértebras Lombares , Modelos Anatômicos , Próteses e Implantes , Fenômenos Biomecânicos
9.
Acta ortop. bras ; 17(4): 207-210, 2009. ilus, graf, tab
Artigo em Inglês, Português | LILACS | ID: lil-525648

RESUMO

INTRODUÇÃO: A fotoelasticidade é utilizada para avaliar as tensões/deformações produzidas nos materiais fotoelásticos, quando submetidos a determinado carregamento, através da observação de efeitos óticos. O desempenho do parafuso e as funções mecânicas estão diretamente relacionados com a qualidade da fixação dos parafusos nas vértebras. A fotoelasticidade é uma ferramenta importante para realizar estudos comparativos desta natureza. OBJETIVO: O objetivo deste estudo foi comparar por meio da fotoelasticidade, as tensões internas produzidas pelo parafuso com 6 mm de diâmetro externo, quando submetido a duas diferentes forças de arrancamento. MATERIAIS E MÉTODOS: Para isso, foram confeccionados quatro modelos fotoelásticos. A simulação foi realizada utilizando duas forças de arrancamento 0,75 e 1,50 kgf. As tensões cisalhantes foram calculadas nos 19 pontos em torno dos parafusos, utilizando o método de compensação de Tardy. RESULTADOS: Os valores das tensões cisalhantes foram maiores quando utilizada a força de arrancamento de 1,50 kgf. CONCLUSÃO: Assim sendo, o parafuso estará mais suscetível ao arrancamento com a aplicação de força de maior intensidade. De acordo com as análises realizadas verificamos também que o local de maior tensão cisalhante foi observado no pico das cristas, principalmente próxima às pontas dos parafusos, independente da força utilizada.


INTRODUCTION: The photoelasticity is used for assessing the tensions/deformations involved in photoelastic materials when submitted to a given load by the observation of optical effects. The screw performance and mechanical functions are directly associated to the quality of the screws fixation in the vertebrae. Photoelasticity is an important tool to perform comparative studies of this nature OBJECTIVE: The aim of this study was to compare, by using photoelasticity, internal stresses produced by the screw with an external diameter of 6 mm, when submitted to two different pullout strengths. MATERIALS AND METHODS: For this, four photoelastic models were produced. The simulation was conducted by using two pullout strengths: 0.75 and 1.50 kgf. The maximum shear stresses were calculated on 19 points around the screws, using the Tardy compensation method. RESULTS: The values of maximum shear stress were higher with the load of 1.50 kgf. CONCLUSION: Thus, the screw will be more susceptible to pullout when heavier loads are applied. According to our analysis, we also found that the site with the highest maximum shear stress was found to be at the peak of creast, particularly near the tips of the screws, regardless of the load employed.


Assuntos
Parafusos Ósseos , Resinas Epóxi , Teste de Materiais , Dispositivos de Fixação Ortopédica , Resinas , Resistência ao Cisalhamento , Aço Inoxidável , Fenômenos Biomecânicos , Elasticidade , Estudos de Avaliação como Assunto , Estudos de Avaliação como Assunto , Resistência à Tração
10.
Braz Oral Res ; 22(2): 125-31, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18622481

RESUMO

The aim of this study was to evaluate the integrity of the external hexagon of an implant system with internal and external hexagons but with prosthetic connection through the external hexagon (Internal Torque, IT) in comparison with that of an implant system with external hexagon with mount (External Hexagon, EH). A device was made to measure the rotational freedom angles between implant and abutment hexagons in 10 implants from each group after the application of surgical placement torques of 45, 60 and 80 Ncm simulating implant locking. The distances between the vertices of the external hexagon were also obtained. Rotational freedom data were subjected to ANOVA and Tukey's test (P < .05) showing no significant difference between the angles of the intact implants (EH - 3.31 +/- 0.41 degrees and IT - 3.30 +/- 0.17 degrees ) and after application of a 45 Ncm torque (EH - 3.27 +/- 0.38 degrees and IT - 3.31 +/- 0.22 degrees ). However, after application of a 60 Ncm torque there were significant differences (IT - 3.40 +/- 0.20 degrees and EH - 4.03 +/- 0.54 degrees ). After application of a 80 Ncm torque, the IT implant presented values of 3.39 +/- 0.21 degrees whereas the EH did not support the torque, suffering deformation of its external hexagon. Within the limits of this study, it can be concluded that the IT implant system may be preferable in clinical situations where implant placement within a certain bone density could generate torques higher than 60 Ncm.


Assuntos
Dente Suporte , Implantes Dentários , Planejamento de Prótese Dentária , Prótese Dentária Fixada por Implante , Análise de Variância , Fenômenos Biomecânicos , Implantes Dentários para Um Único Dente , Teste de Materiais , Rotação , Estresse Mecânico , Torque
11.
Braz. oral res ; 22(2): 125-131, 2008. ilus, graf, tab
Artigo em Inglês | LILACS | ID: lil-485951

RESUMO

The aim of this study was to evaluate the integrity of the external hexagon of an implant system with internal and external hexagons but with prosthetic connection through the external hexagon (Internal Torque, IT) in comparison with that of an implant system with external hexagon with mount (External Hexagon, EH). A device was made to measure the rotational freedom angles between implant and abutment hexagons in 10 implants from each group after the application of surgical placement torques of 45, 60 and 80 Ncm simulating implant locking. The distances between the vertices of the external hexagon were also obtained. Rotational freedom data were subjected to ANOVA and Tukey's test (P < .05) showing no significant difference between the angles of the intact implants (EH - 3.31 ± 0.41° and IT - 3.30 ± 0.17°) and after application of a 45 Ncm torque (EH - 3.27 ± 0.38° and IT - 3.31 ± 0.22°). However, after application of a 60 Ncm torque there were significant differences (IT - 3.40 ± 0.20° and EH - 4.03 ± 0.54°). After application of a 80 Ncm torque, the IT implant presented values of 3.39 ± 0.21° whereas the EH did not support the torque, suffering deformation of its external hexagon. Within the limits of this study, it can be concluded that the IT implant system may be preferable in clinical situations where implant placement within a certain bone density could generate torques higher than 60 Ncm.


Assuntos
Dente Suporte , Implantes Dentários , Planejamento de Prótese Dentária , Prótese Dentária Fixada por Implante , Análise de Variância , Fenômenos Biomecânicos , Implantes Dentários para Um Único Dente , Teste de Materiais , Rotação , Estresse Mecânico , Torque
12.
ImplantNews ; 3(4): 355-359, jul.-ago. 2006. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-457403

RESUMO

Os Implantes originais apresentam uma perda óssea marginal crônica que pode estar ligada à concentração de tensões sobre os implantes após a aplicação de carga. Diferentes tipos de junções pilar/implante poderiam minimizar o problema. Este trabalho analisou a distribuição de tensão sobre os implantes de mesma forma externa, diferindo apenas nas junções: hexágono externo (HE) e hexágono interno (HI). Estas peças foram inseridas em modelos fotoelásticos e submetidas a duas cargas compressivas: axial e deslocada 6,5 mm do centro. Foram analisados 61 pontos sobre o corpo do implante, nos quais os valores de tensão cisalhante máxima foram determinados. Gráficos foram realizados e suas áreas calculadas para os resultados obtidos em todo o corpo do implante e apenas na região de plataforma, ambos sob as duas situações de carga. Não foi encontrada nenhuma diferença estatística significante para carga axial nas duas regiões de análise propostas (“t” de Student, p<0,05). Entretanto, para a carga não-axial foi encontrada diferença significante quando comparado todo o corpo do implante (U de Mann Whitney, p<0,05) e quando analisada somente a região de plataforma (U de Mann Whitney, p<0,05), sendo que nas duas comparações os implantes HI apresentaram menores valores. As diferenças entre as junções sob carga axial foram de 1,28% a mais para HE na análise de todo o corpo do implante e 2,11% a mais para HE na região de plataforma. Quando sob carga não-axial, o Grupo HI apresentou os menores valores e o Grupo HE apresentou 12,93% a mais de concentração de tensão na comparação dos 61 pontos. Nesta mesma situação de carga, quando analisados os primeiros nove pontos, os menores níveis de tensão foram de HI e os maiores de HE com 17,36%.


Assuntos
Fenômenos Biomecânicos , Prótese Dentária Fixada por Implante , Resistência ao Cisalhamento , Planejamento de Prótese Dentária